Public Libraries of Suffolk County, New York

Real-time detection of chemical warfare agents using multi-wavelength photoacoustics, by Kristan Gurtan, Melvin Felton, and Richard Tober

Label
Real-time detection of chemical warfare agents using multi-wavelength photoacoustics, by Kristan Gurtan, Melvin Felton, and Richard Tober
Language
eng
resource.governmentPublication
federal national government publication
Index
no index present
Literary Form
non fiction
Main title
Real-time detection of chemical warfare agents using multi-wavelength photoacoustics
Medium
electronic resource
Nature of contents
dictionaries
Responsibility statement
by Kristan Gurtan, Melvin Felton, and Richard Tober
Series statement
ARL-TR, 4782
Summary
We present a proof-of-concept study designed to investigate the utility of operating a conventional photoacoustic spectroscopy technique in a "multi-wavelength" mode applied to chemical vapor/aerosols for application of trace species detection and identification. The technique involves propagating three or more laser sources through a non-resonate, flow through photoacoustic cell. Each laser source is modulated at a different frequency, chosen at some convenient acoustic frequency. A portion of each laser's power is absorbed by a particular test gas/aerosol that is passing through the PA cell, resulting in a acoustic signal that is found to be proportional to the absorption cross section of the gas/vapor at the particular laser wavelength. A superposition of frequency component (equal to the number of laser wavelengths used), combines with the ambient acoustic noise spectrum and is recorded by an electret microphone housed in the photoacoustic cell. The signal is deconvolved using phase sensitive detection where each component (one corresponding to a particular modulation frequency for a particular laser) is amplified and recorded as function of species concentration. Ratios of the resultant absorption information are used to produce an identifiable metric that remains constant for all concentrations. For the study presented here, we used 3 laser wavelengths all lying in the spectrally rich long-wave infrared (LWIR), i.e., 8.72, 9.27, and 10.35 um. Test nerve agents simulants include (but not limited to), diethyl phosphonate (DEMP), dimethyl methylphosphonate (DMMP), and diisopropyl phosphonate (DIMP). Measured photoacoustic absorption results compare well with Fourier Transform Infrared (FTIR) analysis that is conducted in situ with the photoacoustic portion of the measurement
Target audience
adult
Content

Incoming Resources